I’m syncoiding from my normal RAIDz2 to a backup mirror made of 2 disks. I looked at zpool iostat and I noticed that one of the disks consistently shows less than half the write IOPS of the other:

                                        capacity     operations     bandwidth 
pool                                  alloc   free   read  write   read  write
------------------------------------  -----  -----  -----  -----  -----  -----
storage-volume-backup                 5.03T  11.3T      0    867      0   330M
  mirror-0                            5.03T  11.3T      0    867      0   330M
    wwn-0x5000c500e8736faf                -      -      0    212      0   164M
    wwn-0x5000c500e8737337                -      -      0    654      0   165M

This is also evident in iostat:

     f/s f_await  aqu-sz  %util Device
    0.00    0.00    3.48  46.2% sda
    0.00    0.00    8.10  99.7% sdb

The difference is also evident in the temperatures of the disks. The busier disk is 4 degrees warmer than the other. The disks are identical on paper and bought at the same time.

Is this behaviour expected?

    • lightrush@lemmy.caOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      edit-2
      2 months ago

      Interesting. SMART looks pristine on both drives. Brand new drives - Exos X22. Doesn’t mean there isn’t an impending problem of course. I might try shuffling the links to see if that changes the behaviour on the suggestions of the other comment. Both are currently hooked to an AMD B350 chipset SATA controller. There are two ports that should be hooked to the on-CPU SATA controller. I imagine the two SATA controllers don’t share bandwidth. I’ll try putting one disk on the on-CPU controller.

      • Shadow@lemmy.ca
        link
        fedilink
        English
        arrow-up
        5
        ·
        2 months ago

        You could just swap the two disks and see if it follows the drive or the link.

        If the drive, rma it. I don’t put a lot of faith in smart data.

        • lightrush@lemmy.caOP
          link
          fedilink
          English
          arrow-up
          2
          ·
          2 months ago

          Turns out the on-CPU SATA controller isn’t available when the NVMe slot is used. 🫢 Swapped SATA ports, no diff. Put the low IOPS disk in a good USB 3 enclosure, hooked to an on-CPU USB controller. Now things are flipped:

                                                  capacity     operations     bandwidth 
          pool                                  alloc   free   read  write   read  write
          ------------------------------------  -----  -----  -----  -----  -----  -----
          storage-volume-backup                 12.6T  3.74T      0    563      0   293M
            mirror-0                            12.6T  3.74T      0    563      0   293M
              wwn-0x5000c500e8736faf                -      -      0    406      0   146M
              wwn-0x5000c500e8737337                -      -      0    156      0   146M